On the use of the core assembly machine plastic bag frequency transformer power transmission mode
Our company specializes in producing high-frequency Hui Yue Technology transformer core assembly machines, high-frequency transformer plastic bag machine, high-frequency transformer assembly plastic bag machines and other automated equipment, following by Hui Xiao Bian tell you more of what the high-frequency transformer power transmission system .
Transformer transmission, i.e. applied in the transformer primary winding alternating voltage, generating magnetic flux variation in the core, so that the secondary winding induced voltage, applied to the load, so that the electrical power transferred from the primary to the secondary. Transmission power size is determined by the induced voltage, which is independent of the magnetic flux density depends on the variable ΔB.ΔB and permeability per unit time, while the saturation magnetic flux density Bs and residual magnetic flux density Br relevant from saturation magnetic flux density point of view, Bs in descending order of various soft magnetic materials are: iron-cobalt alloy is 2.3 ~ 2.4T, silicon is 1.75 ~ 2.2T, iron-based amorphous alloy is 1.25 ~ 1.75T, iron-based nanocrystalline alloy crystallites 1.1 ~ 1.5T, iron-silicon aluminum alloy is 1.0 ~ 1.6T, high permeability iron-nickel permalloy is 0.8 ~ 1.6T, cobalt-based amorphous alloy is 0.5 ~ 1.4T, iron aluminum is 0.7 ~ 1.3T, iron nickel-based amorphous alloy is 0.4 ~ 0.7T, Mn-Zn ferrite is 0.3 ~ 0.7T. as electronic transformer core materials, silicon and iron-based amorphous alloy dominant, while Mn-Zn ferrite at a disadvantage
(about the Magnetic core Assemble machine)