Parameter setting of HY-Z002 fully automatic two - cylinder vacuum - containing
HY-Z002 fully automatic dual cylinder vacuum impregnation machine: PLC control, as long as the leaching parameters of products (vacuum, dipping time, defoaming, exhaust and so on) set up, press the "start" button can be run set will save in the PLC controller, no longer set can be operation has completed a number of products, after use impregnated with this product, call this operation data. After the completion of the automatic open cover, then how to set up the parameters set? The following Xiaobian tell you by Hui more detailed.
Other parameters according to the user needs to set, < immersion height > if set exceeds the actual mechanical travel will automatically be modified into maximum mechanical trip. If the stepper motor a not normal, howling, and pallet's actual position and painting surface display position is inconsistent, please will < pallet speed > adjustable small (the best between the 1.0-30.0mm/S) and closed power 2 minutes again after power on reset. < vacuum oil immersion > and < secondary vacuum > can only be set to - 100 to 0 between negative, in front of a numeric input first according to the keyboard popup <+/-> key to switch to enter a negative number. If does not need the defoaming function, please < defoaming time > and < defoaming interval > is set to 0, if you set the < defoaming time > and < defoaming interval >, in the automatic operation of the immersion process will be according to the set value timing opening and closing the intake valve.
HY-Z002 fully automatic dual cylinder vacuum with a submerged object in kind: